Product Overview:

LCX-MNAC series grid simulator (source & load integrated unit) is designed for R&D, quality verification and production testing of new energy power generation equipment.

It supports four-quadrant operation and energy feedback, with built-in voltage waveform editing function. It complies with UL 1741SA / IEEE 1547 / IEC 62116 standards.

Users can adjust voltage, frequency, phase shift, three-phase unbalance, flicker and other parameters to simulate various grid operating conditions.

The energy regenerative function feeds power back to the grid, saving energy and lowering operating costs.

Typical Applications:

· R&D and factory testing of photovoltaic inverters

· Smart grid related power equipment verification

· EV on-board charger & AC/DC charging pile R&D and inspection

· New energy power generation products quality certification test

· Low voltage ride-through (LVRT) and grid disturbance simulation test

LCX grid simulator, for inverter R&D test. High precision output, simulates abnormal grid conditions in new energy laborator
LCX grid simulator, for inverter R&D test. High precision output, simulates abnormal grid conditions in new energy laborator
LCX grid simulator open cabinet view. Modular power design, easy maintenance, suitable for photovoltaic inverter performance
LCX grid simulator open cabinet view. Modular power design, easy maintenance, suitable for photovoltaic inverter performance

Technical Specifications:

1. Output Configuration

Optional single-phase or three-phase AC output.

2. Standard Compliance

Supports testing for PV inverters, smart grid and electric vehicle related products, conforms to UL 1741SA, IEEE 1547, IEC 62116.

3. Signal & Disturbance Simulation

Synchronized TTL signal output along with voltage variation.

LIST / STEP / PULSE modes for power line disturbance (PLD) simulation.

Adjustable firing angle 0~360° for voltage waveform.

Voltage dip & transient variation simulation for LVRT low voltage ride-through test.

4. Waveform & Measurement Function

Measurement of each order current harmonic component.

Synthesis of distorted waveforms including harmonics and inter-harmonics.

5. Core Advantage

Four-quadrant operation with energy regenerative feedback to grid, low energy consumption.

LCX grid simulator rear panel. Stable connection & efficient heat dissipation, supports long-hour continuous reliability
LCX grid simulator rear panel. Stable connection & efficient heat dissipation, supports long-hour continuous reliability